Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V1.9.0.0
-
Component/s: None
-
Labels:
-
Account:SPC Profinet Core (SPCPROFINET)
Description
The record object ARData lists all currently established ARs with their properties. This object returns wrong content after the following sequence:
- An AR was established with IRT
- The AR is released and again established as RT AR (without IRT)
After that the object contains an IRInfoBlock for the RT-AR although such an block was not sent by the controller.
It is expected that IRInfoBlock is generated only when it was sent by the controller during connect.
Attachments
Issue Links
- is blocked by
-
PSPNSV4-1150 Upgrade Profinet Core to V1.9.0.6
- Closed
- is cloned by
-
PSPNCORE-351 Record object ARData may contain wrong content once IRT was used
- Closed
- relates to
-
PSPNSV5-129 Upgrade Profinet Core to V1.9.0.5
- Closed