Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-346

Record object ARData may contain wrong content once IRT was used

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.9.0.0
    • Fix Version/s: V1.9.0.5, V1.10.0.0
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Core V1 operational (SPCPROFINET)

      Description

      The record object ARData lists all currently established ARs with their properties. This object returns wrong content after the following sequence:

      1. An AR was established with IRT
      2. The AR is released and again established as RT AR (without IRT)

      After that the object contains an IRInfoBlock for the RT-AR although such an block was not sent by the controller.

      It is expected that IRInfoBlock is generated only when it was sent by the controller during connect.

        Attachments

          Issue Links

            Expenses

              Activity

              There are no comments yet on this issue.

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: