Details
-
Type: Change
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Component/s: Controller
-
Labels:None
-
Account:SPC Profinet Core (SPCPROFINET)
Description
When using the Profinet IO Controller with a large configuration, frame loses can occur due to the limited network switch buffer resources. This behavior can be improved by using the INTRAM2 segment as additional buffer.
The startup parameters of the PnC Driver Ethernet Adapter shall be extended in order to conditionally enable the use of INTRAM2 memory.
Attachments
Issue Links
- blocks
-
PSPNMV3-580 Upgrade Profinet Core to V1.6.0.7
- Closed
- is blocked by
-
PSPNMV3-574 sometimes unexpected AR abort when establishing a lot of ARs in parallel
- Closed
- relates to
-
PSPNCORE-326 Unexpected AR Abort upon receiving Application Ready before Parameter End confirmation
- Closed