[DHCP/BOOTP] IP address is still in use after physical link down/up event although DHCP/BOOTP server is not available (certification issue)

    Details

    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      The device is configured for DHCP/BOOTP and has been successfully assigned a valid IP address. ACD is turned OFF.

      After a physical link down/up the device starts sending DHCP-DISCOVER (or BOOT REQUEST) frames, which is correct.
      However, the IP address that was in use before the link down/up event is still in use and the device still communicates via this IP address (e.g. ICMP ping etc.), which is unexpected.

      After a link down/up event, the IP address must be dropped in case DHCP/BOOTP is active. The device is required to obtain the IP from the DHCP/BOOTP server again.

      Note: This behavior can cause an EtherNet/IP device to fail the conformance test.