Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-895

CIP TCP/IP Interface object link up behavior is not correct (certification issue)

    Details

    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      After link down/up event, the device does not evaluate the current value of attribute 3 before re-configuring the TCP/IP stack.

      This is defined in table 5-4.1 in CIP Volume 2 Edition 1.23 (see below).
      The yellow marked step is not executed. The device rather uses the "old" TCP configuration.

       

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: