CIP TCP/IP Interface object link up behavior is not correct (certification issue)

    Details

    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      After link down/up event, the device does not evaluate the current value of attribute 3 before re-configuring the TCP/IP stack.

      This is defined in table 5-4.1 in CIP Volume 2 Edition 1.23 (see below).
      The yellow marked step is not executed. The device rather uses the "old" TCP configuration.

       