Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-789

Class1 connection cannot be established under certain conditions when assembly instance 1 is supported by the device

    Details

    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      If assembly instance 1 is registered at the stack as input or output assembly it happens that a connection that does not address this instance will not be established. Instead the extended error 0x321 will be returned by the device (forward open response).

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: