Class1 connection cannot be established under certain conditions when assembly instance 1 is supported by the device

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.2.0.0, V2.3.0.0
    • Fix Version/s: V2.1.0.8, V2.2.0.3, V2.3.0.1, V2.3.1.0
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      If assembly instance 1 is registered at the stack as input or output assembly it happens that a connection that does not address this instance will not be established. Instead the extended error 0x321 will be returned by the device (forward open response).