Details
-
Type: Change
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V2.5.1.0
-
Labels:None
-
Account:SPC EthernetIp Core (SPCETHERNET)
Description
Currently the packet EIP_OBJECT_AS_TRIGGER_TYPE_IND is sent to the application before the connection is fully accepted. This can lead to situations where the trigger type is indicated to the host, but the connection is rejected afterwards.
Therefore, the trigger type indication shall only be sent when the connection is accepted (forward open response is sent with status "Success").
Attachments
Issue Links
- is blocked by
-
PSEIS-974 Enable the host application to trigger "application triggered" assembly data indepenedent of each other
- Closed
- relates to
-
PSEIPCORE-296 [Scanner] "Application triggered" or "Change of State triggered" originator connections always run in cyclic trigger mode