AcdFault bit stays zero in address conflict state

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.11.2.0, V2.12.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      In case an address conflict occurs, the AcdFault (bit 7 in Status attr. 1 of TCP/IP object 0xF5) remains zero, which is not expected. According to CIP Volume 2 the bit must be set.