Uploaded image for project: 'PROFIBUS Slave'
  1. PROFIBUS Slave
  2. PSDPS-453

feature: Implement a mechanism to read out some parameters from the stack

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.8.0.0
    • Fix Version/s: V2.8.1.0
    • Component/s: Documentation, Firmware
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      DPS API manual states in chapter 5.3.2 Parameterization that the DPV standard parameter (i.e. watchdog settings, ident number etc.) can be sent to host application with PROFIBUS_FSPMS_CMD_CHECK_USER_PRM_IND. But it is not implemented this way. The user gets only the UserPrm (from byte 8 on), but not the norm specific parameter.

      A new packet shall be defined to let the user to read out additional parameter from the stack (i.e. Norm parameter, diagnosis etc.)

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    RHornung Ralf Hornung
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: