      Description

      DPS API manual states in chapter 5.3.2 Parameterization that the DPV standard parameter (i.e. watchdog settings, ident number etc.) can be sent to host application with PROFIBUS_FSPMS_CMD_CHECK_USER_PRM_IND. But it is not implemented this way. The user gets only the UserPrm (from byte 8 on), but not the norm specific parameter.

      A new packet shall be defined to let the user to read out additional parameter from the stack (i.e. Norm parameter, diagnosis etc.)