Uploaded image for project: 'DeviceNet Slave'
  1. DeviceNet Slave
  2. PSDNS-467

Stack does not detect missing 24V after Channel Init

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.5.2.0, V2.6.0.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC DeviceNet Slave (SPCDEVICESL)

      Description

      After System restart , tested stack has following condition:
      ulCommunicationState = 0x00000004 Operate
      ulCommunicationError = 0xC062002C "24V Network Power Missing"
      ulErrorCount = 0
      NCF_ERROR flag is ON

      After Channel Init , tested stack has following condition:
      ulCommunicationState = 0x00000004 Operate
      ulCommunicationError = 0x00000000
      ulErrorCount = 0
      NCF_ERROR flag is OFF
      flag 24V_NETWORK_POWER = FALSE

      I am expecting stack to detect missing 24V Bus power for each of initialization request - System Restart and Channel Init