Details
-
Type: Requirement
-
Status: Closed
-
Priority: Minor
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: V4.4.0.0
-
Labels:None
-
Requirements Revision:1
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
For applications implementing the PROFIenergy profile it is required to generate Alarms with AlarmType "Status". For applications implementing the PROFIsafe profile it is possible to create alarms with AlarmType "Upload and Retrieval".
The existing API (of PNS V3.12.0.0) needs to be provided by the protocol stack to allow applications to generate specific alarms.
The following AlarmTypes shall be supported by the new API service:
Name Value
|
Process 0x0002
|
Status 0x0005
|
Update 0x0006
|
Upload & Retrieval. 0x001E
|
Manuf.-specif. 0x0020-0x007F
|
Profile-specif. 0x0080-0x00FF
|
The API shall be the same as implemented in PNSv3.
Attachments
Issue Links
- clones
-
PRODPNS-172 Feature: Add API for application to generate Alarms with specific AlarmTypes
- Closed
- is blocked by
-
PSPNSV4-615 Feature: Implement API for UserSpecific Alarms
- Closed
- mentioned in
-