Details
-
Type: Requirement
-
Status: Closed
-
Priority: Minor
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: V3.12.0.0
-
Labels:None
-
Requirements Revision:1
Description
For applications implementing the PROFIenergy profile it is required to generate Alarms with AlarmType "Status". For applications implementing the PROFIsafe profile it is possible to create alarms with AlarmType "Upload and Retrieval".
Thus such an API needs to be provided by the protocol stack to allow applications to generate specific alarms. The API service shall work the same way as current service for ProcessAlarms is used.
The following AlarmTypes shall be supported by the new API service:
Name Value
|
Process 0x0002
|
Status 0x0005
|
Update 0x0006
|
Upload & Retrieval. 0x001E
|
Manuf.-specif. 0x0020-0x007F
|
Profile-specif. 0x0080-0x00FF
|
Attachments
Issue Links
- is blocked by
-
PSPNS-2557 Feature: Add API for application to generate Alarms with specific AlarmTypes
- Closed
- is cloned by
-
PRODPNSV4-60 Feature: Implement API for application to generate Alarms with specific AlarmTypes
- Closed