Details
-
Type: User Story
-
Status: Closed
-
Priority: Minor
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: V3.2.0.0
-
Component/s: None
-
Labels:None
-
Account:SPC Profinet Master (SPCPROFINETMA)
Description
According to Profinet specification every Profinet device (IO Devices as well as IO Controllers) shall offer writable SNMP objects. These objects can be written and after a powercycle the written values need to be visible again.
In addition it is required to store NameOfStation and IP parameters set via DCP.
To support this the firmware needs
- an API to inform the user about parameters that need to be stored
- a defined way how to restore the data prior to Sycon.net database evaluation (enforce application controlled startup)
- fix size of packet shall be 8 KB (to have some reserve for future use)
Attachments
Issue Links
- is blocked by
-
PSPNMV3-295 Implement mechanism to indicate / receive remanent data to / from host application
- Closed
- relates to
-
PRODPNMV3-83 NameOfStation and IP shall be set via DCP via the network in order to pass IO Controller certification
- Closed