Details
-
Type: User Story
-
Status: Closed
-
Priority: Minor
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: V3.2.0.0
-
Component/s: None
-
Labels:None
-
Account:SPC Profinet Master (SPCPROFINETMA)
Description
There exist some use cases where it would be good that the IO Controller is not setting the IP address of a configured IO Device.
Instead IO Controller shall just identify the IO Device by NameOfStation and if he finds the IO Device he shall use the IP that has been assigned to IO Device.
If the IO Device is not reachable by IP services the IO Device can not be taken in data exchange.
This shall be a "per Device" setting.
Attachments
Issue Links
- is blocked by
-
PSPNMV3-289 Feature: Add API to configure which IP to use for AR (given by engineering or found in network)
- Closed
- mentioned in
-
Page Loading...