Details
-
Type:
User Story
-
Status: Closed
-
Priority:
Minor
-
Resolution: Done
-
Affects Version/s: None
-
Labels:
-
Account:SPC EthernetIp Slave (SPCETHERNE)
Description
User Story:
As a host application, I want to forward application specific fault states to the EtherNet/IP firmware so that the state becomes visible through EtherNet/IP means (Module Status LED and the corresponding Identity status (5) and state (8) attributes).
Background information:
With the V2 firmware generation, the host application had the possibility to set bit 8-11 of Identity status attribute 5.
This in turn also influenced the module status LED and state Identity attribute 8.
We need to provide a similar mechanism for the EtherNet/IP Core V3 generation.
In addition, the host application shall be able to modify bit 0 "Owned" and bit 2 "Configured".
|
Attachments
Issue Links
- relates to
-
PSEIP-288 Add API mechanism for altering device status (Identity attributes 5/8) and signaling of application faults
-
- Closed
-
-
PRODEISV3-457 Enable host application to set Identity status attribute 5
-
- Closed
-