      Description

      Definition:
      SYS LED (green) On: Operating System running

      The rcX do not set the SYS LED state correctly, when the driver RX_HIF_SET_T atrXHif and the function "MidSysDpmInit" is used.
      The function "SetReadyLed" (RDYRUN green) is called if the variables "fMidSysHifReady", "fMidSysReady" and "fTasksReady" set to TRUE.

      In the case the Host Interface is needed for the initalization of the stack, but the application layer do not access the Host interface, then the function "MidSysDpmHifReady" is not called and the variable fMidSysHifReady is not set to TRUE. The result is the SYS LED is yellow and the rcX and the stack is running.