Uploaded image for project: 'Sercos Slave'
  1. Sercos Slave
  2. PSSCS-841

C1D error occured but no error code in S-0-0390

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.8.0
    • Fix Version/s: V3.1.18.0
    • Component/s: Firmware
    • Labels:
      None

      Description

      If the slave is in CP4 and both wires get disconnected the slaves drops back to NRT (through: Amount of MST losses in CP3 & CP4 exceeded). Now the red LED turns on because this is an C1D Error and the S-0-0099 is required to turn the LED out.

      Expected an Error-Code in S-0-0390: 4001 Error of MST losses. See: https://wiki.sercos.org/rc/SCP_StatusCodes
      And the LED: https://wiki.sercos.org/rc/FG_Diagnosis

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  DJanssen Denis Janssen
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: