Sequence of MDT/AT function calls false

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.2.2.0
    • Fix Version/s: V3.2.3.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Sercos Slave (SPCSERCOSSL)

      Description

      The old modes Bus Sync and Triple Buffer start with producing followed by consuming and so on. The new mode SIII_SL_AP_SET_CONFIGURATION_DEVICE_PROCDATA_MODE_SEPARATE_AT_CALLBACK started with consuming followed by producing and so on. This leads to a missing Handshake in AP task a few cycles after entering CP4. Change the new mode according to the old modes.