Ethernet frame buffer from DrvEth must not be considered 4 byte aligned

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.3.0.3 (open), V2.3.1.0
    • Labels:
      None
    • Account:
      SPC TCP_IP (SPCTCPIP)

      Description

      When obtaining a frame from the DrvEth component, the payload data pointer must not be considered to be 4 bytes aligned. This can cause the firmware to crash in case that buffer is accessed with instructions that require 4 bytes alignment.