Uploaded image for project: 'PROFINET IO-Device V5'
  1. PROFINET IO-Device V5
  2. PSPNSV5-80

[GSDML] Inconsistent version number given for PNIO_Version

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V5.0.3.0
    • Fix Version/s: V5.1.0.1, V5.1.1.0, V5.2.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The GSDML files provided are according GSDML specification V2.34

      However the DeviceAccessPoints inside GSDML files claim conformance to PNIO_Version 2.35. This is inconsistent as this PNIO_Version can not be used together with GSDML V2.34

      The PNIO_Version needs to be set to 2.34.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: