Uploaded image for project: 'PROFINET IO-Device V5'
  1. PROFINET IO-Device V5
  2. PSPNSV5-707

Unexpected behavior after connecting with big IOCR lengths

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When a controller establishes an connection with IOCR data lengths in range "1437" to "1440" a buffer overflow occurs resulting in unexpected behavior afterwards. The problem is most likely seen with a firmware with disabled shared device (taglist) during certification testcases Behavior Scenario 7, 8 and 9.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: