Uploaded image for project: 'PROFINET IO-Device V5'
  1. PROFINET IO-Device V5
  2. PSPNSV5-522

Singleport firmware unresponsible on network when trying to establish a second IO AR

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V5.5.1.0
    • Fix Version/s: V5.5.2.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When using the singleport firmware and an IO AR is established all is fine. When now a second IO-AR shall be established, the netX does not respond at all to the Connect Request. In addition, it stops sending LLDP, stops responding to DCP and after a while even stops sending cyclic frames to the first, already established IO AR.

       

      The regular firmware with support for two Ethernetports is not affected by this issue.
       

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: