Uploaded image for project: 'PROFINET IO-Device V5'
  1. PROFINET IO-Device V5
  2. PSPNSV5-481

Receiving a Release request with wrong ARUUID is not rejected but instead aborts the AR

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V5.5.0.0
    • Fix Version/s: V5.5.0.2, V5.5.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When an IO Controller sends a Release Request but uses a wrong ARUUID, the AR is aborted and the Release Request is positively answered.

      It is expected that a Release Request with wrong ARUUID is rejected and the AR is kept stable.

        Attachments

          Issue Links