Details
-
Type: Change
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Labels:
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
As netX90 Usecase C firmware does not support fast SendClock cycles, the GSDML file for PNSV5.3 shall be extended.
For netX90 GSDML file:
- the existing DAP for 5.1 shall be changed to " V5.1.0 - V5.1.x". The OrderID shall be changed to 7833.000. Nothing more shall be changed.
- the existing DAP for 5.2 shall be changed to "V5.2.0 - V5.2.x". The OrderID shall be changed to 7833.000. Nothing more shall be changed.
- the existing DAP for 5.2 SR shall be completely removed
- later we will manually generate a SR-specific GSDML file for delivery of SR firmware
- A new DAP for V5.3 shall be added.
- It shall be named "NETX 90 Usecase A RE/PNS V5.3.0 - V5.x"
- It shall contain the same features as the Dap "5.2.0"
- It shall use OrderID 7833.000
- A second new DAP for V5.3 shall be added.
- It shall be named "NETX 90 Usecase C RE/PNS V5.3.0 - V5.x"
- It shall use OrderID 7833.001
- It shall contain the same features as the new 5.3 Usecase A Dap BUT
- SendClockFactors smaller 1ms shall be removed
- MinDeviceInterval shall be set to 1ms
For "cifx netX90" GSDML file:
- simply adjust the SendClock and MinDeviceInterval in existing DAPs and do not rename anything (same values as new Usecase C DAP)
- the products have not yet been sold to customers and thus we can simply change the parameters
For NRP90 GSDML file
- the DAP "H90-RE\F8D8/PNS" represents the Usecase C firmware.
- It shall be adjusted in the same way as the "cifX netX90" GSDML file