Uploaded image for project: 'PROFINET IO-Device V5'
  1. PROFINET IO-Device V5
  2. PSPNSV5-121

Out of Memory due to memory fragmentation

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V5.1.1.0
    • Fix Version/s: V5.2.1.0, V5.3.0.0
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Afterwards booting a netX4000 device with database configuration in filesystem, it might be not possible to reconfigure the device with another packet or database config. In particular the following sequence wail fill:

      1. Download database to netX4000
      2. Reset netX 4000 with database config in file system
      3. Delete database files from filesystem
      4. Execute a channel init to reload configuration -> unconfigured
      5. Send Set Configuration Service
      6. Execute a channel init to load packet configuration -> out of memory error

      The Problem does not occur, if in 2) a channel init is executed instead of reset.

      The problem might not be limited to netX4000 firmware.

      It is expected that the configuration is accepted.

        Attachments