Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-973

[GCI-adapter]: reading I&M0 data returns wrong data after first configuration cycle

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V4.4.4.0
    • Fix Version/s: V4.4.5.0
    • Labels:
      None
    • Sprint:
      aktuelle Aufgaben
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the netX90 firmware is configured by SetConfiguration Request which configures the stack to handle I&M data and then I&M0 is read the I&M0 data returned is invalid (contains only character 0x20).

      If now the stack is deconfigured (ConfigDelete, ChannelInit) and then again configured by means of SetConfiguration Request and now I&M0 data is read at least some parts of I&M0 data are set as expected.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: