Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-831

too much data delivered in case of partial read for ModuleDiffBlock

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.3.0.0
    • Fix Version/s: V4.4.0.1, V4.4.2.0, V4.5.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case ModuleDiffBlock is read from IO Controller with expected data length 0 (or smaller value than acutal size of ModuleDiffBlock) the protocol stack generates a positive read reasponse containing the whole ModuleDiffBlock. Thus more data than allowed is returned.

      It is expected that an error code is delivered instead.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: