Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-708

FrameSendOffset in IOCR block is not corretly checked.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Won't Fix
    • Affects Version/s: None
    • Fix Version/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW 50-51
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      During connection, IOCR blocks are accepted by the device despit unvalid FrameSendOffset. The device have to refuse IOCR block for non-IRT IOCR with a FrameSendOffset unequal to 0xFFFFFFFF.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    ATilatti ATilatti (Inactive)
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: