Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-70

unexpected handling of Storing NameOfStation when .nxd database is used

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.6.1.0
    • Fix Version/s: V3.6.2.0
    • Labels:
      None
    • Sprint:
      PI Sprint KW 16/17
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The Name of Station from network (DCP Set Name) is stored in NWID.NXD file. This is different to V3.4 and V3.5 (but okay).

      When configuration download was done through DPM (CIFX driver), original
      NWID.NXD file will be loaded on driver reload and overwrite the Name of Station set from network.
      Thus the NameOfStation set vie the bus is lost.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: