Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-645

Use FSPM profinet status codes on invalid Read/Write Record Service response packet from application

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V4.3.1.0, V4.4.0.0
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW 36-37, PI Sprint 2017 KW 38-39
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the application responds an Read/Write Record service with an unexpected error code, packet length or invalid parameters, an FSPM (0x81814Exx) status code shall be used when generating the RPC response to the profinet controller. This ensures, that unexpected invalid behavior of an application can be easily detected upon certification tests and does not lead to unexpected behavior in field later on.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: