Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-643

Adjust sysDescription for recommended value

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V4.3.1.0, V4.4.0.0
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW 36-37
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When reading the SNMP sysDescr value a Hilscher specific coding is returned by the protocol stack. According to profinet specification it recommended to use the same coding for SNMP sysDescr object as used for lldpLocChassisId in multiple interface mode. The implementation should be changed to use the recommended encoding.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: