Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-621

IOxS set to GOOD by default in case of correct module/submodule IDs but wrong IO data length

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.0.0.0
    • Fix Version/s: V4.3.1.0, V4.4.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If a plugged and an expected IO-submodule has difference only in number of provided (or consumered) bytes (module-id and submodule-id are the same) the related IOPS (IOCS) are set to GOOD (0x80).

      This problem occurs only in case of a mismatch between GSDML file information and protocol stack configuration, e.g. GSDML files defines other data lengths than used when configuring the protocol stack. This is an application error.

        Attachments

        1. ContrDev_DiffIOsubmodule.py
          2 kB
          Artem R. [X]

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  Artem Artem R. [X] (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: