PNS_IF_RESET_FACTORY_SETTINGS_IND contains wrong usResetCode in case of "FactoryReset"

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.2.0.17
    • Fix Version/s: V4.2.0.18, V4.2.3.0, V4.3.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      According to API manual in the PNS_IF_RESET_FACTORY_SETTINGS_IND indication the "usResetCode" should be set to 8 in case of "FactoryReset" but really indicated with 16.