Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-573

Occasionally no Connect response in case of Advanced Startupmode with FSU

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.1.0.0, V4.2.0.0
    • Fix Version/s: V4.2.0.17, V4.3.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Sometimes no connect response is sent when the PROFINET controller connects using advanced startup mode and FSU. In that case the application might receive an unexpected packet with command code 0. Afterwareds a connection is not established and all other RPC services are blocked as well.
      The problem occurs when the protocol stack generates the PNS_IF_PARAMET_SPEEDUP_SUPPORTED_IND while the application has not fetched all pending packets from receive mailbox.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  AMesser Andreas Messer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: