Wrong error code in case of connect with invalid slot/subslot

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V4.2.0.17, V4.2.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When an ExpectedSubmoduleBlockReq contains a Slot/Subslot which is not defines according to GSDML, the device returns an invalid error code. Depending on configuration following errors might occur:

      • 0xDB814007 "Out of resources"
      • No error but module diff block says 'no module/submodule'
        According to specification the error codes
      • 0xDB810306 "Invalid Slotnumber"
      • 0xDB810310 "Invalid Subslotnumber"
        shall be used in that case.