Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-538

In read of DiagnosisData the ChannelProperties.Specifier in case of Maintenance != Fault is wrong

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.2.0.13
    • Fix Version/s: V4.2.1.0
    • Labels:
      None
    • Sprint:
      PI Sprint 2016 KW 50/51
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In RecordDataRead/DiagnosisData/ChannelDiagnosis the ChannelProperties.Specifier is set to "appear" in case if ChannelDiagnosisData/ChannelProperties.Specifier is set to appear but ChannelDiagnosisData/ChannelProperties.Maintenance" not set to "Fault" - in this case the ChannelProperties.Specifier should be set to "disappear".

      It is also applied to other types of diagnoses (ExtChannel Diagnosis, ManufacturerSpecificDiagnosis and QualifiedChannelDiagnosis)

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  Artem Artem R. [X] (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: