Device related and API related diagnosis-indexed deliver the same set of diagnosis

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.2.0.2
    • Fix Version/s: V4.2.0.6, V4.2.1.0
    • Labels:
      None
    • Sprint:
      PI Sprint 2016 KW 18/19
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If an application configures two subslots with different API's and adds diagnosis for both, the read record from index 0xF80C (Diagnosis, Maintenance, Qualified and Status for one device) should deliver all diagnosis entries and read from index 0xF00C (Diagnosis, Maintenance, Qualified and Status for one API) only for one API.
      Curent implementation delivers the same diagnosis set in both cases.