depending on amount of configured ARs the amount of supported submodules shall be adjusted by the firmware

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.2.0.0
    • Fix Version/s: V4.2.0.3, V4.2.1.0
    • Labels:
      None
    • Sprint:
      PI Sprint 2016 KW 15
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      By default the firmware will support 4 IO ARs and in total 32 submodules.

      If the amount of supported IO ARs is reduced to 1 or 2 via taglist than up to 64 submodules shall be supported by the firmware.
      The taglist shall not offer a field with amount of submodules, this shall be derived from the amount of ARs.