Reject IRT Configuration with invalid MaxBridgeDelay

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V4.1.2.0, V4.2.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      As described in IRT Engineering specification the value of PDIRData.PDIRGlobalData.MaxBridgeDelay shall be 100ns bigger than the BridgeDelay of GSDML file.

      If this is not done by Engineering PDIRData record shall be rejected with an error (invalid parameter, the last byte of error code shall be set to a Hilscher specific value to indicate the root cause of negative response).