Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-28

PNS_IF_AR_CHECK_IND does not contain the CMInitiatorUUID as stated in API Manual

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.6.0.0
    • Fix Version/s: V3.6.2.0
    • Labels:
      None
    • Sprint:
      PI Sprint KW 21 2014
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      the new definition of stack v3.5 of the content of the AR Check Indication is not respected by the IO Device stack v3.6

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: