Connect Request with Shared Input is accepted although feature not supported

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: V3.6.0.0
    • Fix Version/s: V3.6.2.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The Stack accepts connect requests with shared input flag set in expected submodule blocks but behaves like non-shared input flag set. Furthermore the GSDML file states that shared input is not supported. The Stack shall reject connect requests where the shared input flag is set.