Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-184

AR not established if fix port mode configured

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.6.13.0
    • Fix Version/s: V4.0.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the controller requests fixed mode of a port, the device reconfigures the phy after every Parameter End. As a result the link will be lost and the AR aborts. The secenario repeats and no AR is established.

      The problem is caused by a bad Ether Mau Type comparison in case of fixed mau settings.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: