Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V4.8.0.0
-
Fix Version/s: V4.8.0.9, V4.9.0.3, V4.9.1.0 (trunk)
-
Labels:None
-
Account:SPC Profinet Slave V4 operational (SPC-PSPNSV4-OPERATIONAL)
Description
Sometimes, the cable delay meassurement between netX100 and e.g. SCALANCE switch is not working as expected after power cycling the netX. The netX meassures valid cable delay value, however the SCALANCE calculates a wrong delay with a large deviation between the two values.
Due to the large deviation, the netX cannot synchronize to SyncMaster and thus the cyclic connection is not established.
The issue is related to first synchronization of netX to SyncMaster after powerup.
Attachments
Issue Links
- is blocked by
-
PSPNCORE-854 Wrong response delay value during sync slave startup on netX500/100 chipset
-
- Closed
-
- requested
-
PSPNSV4-1626 Upgrade Profinet Core to V1.16.0.2
-
- Closed
-
-
PSPNSV4-1627 Upgrade Profinet Core to V1.15.0.10
-
- Closed
-