Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.6.2.0
    • Fix Version/s: V4.7.0.4, V4.7.2.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      This update fixes an issue with wrong MDI / MDIX settings in case of fix MAUType.

      In case a port is set to fix MAUType (e.g. 100MBit/s FullDuplex), a fix MDI / MDIX value shall be used. Current firmware uses AutoMDI instead. This will always lead to a valid link, however link establishment may take longer than expected.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: