Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-1409

IRT not possible for some valid PDIRData codings with reduction

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the Profinet IO Controller configures the device for IRT mode with reduction for the IOCRs, the firmware does not establish IRT connection when PDIRBeginEndData has less phases than reduction. This is however a valid encoding.

      It is expected, that the firmware accept the coding and configures the port phases independend of the IOCR settings.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: