Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-1349

Unexpected/erronous SetConfiguration Service not properly rejected

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V4.6.1.0
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When application sends an unexpected or erronous SetConfiguration Service which is rejected by the firmware, a subsequent ChannelInit might still activate the configuration.

      This may happen in the following cases:

      • SetConfiguration Service used while Database Config in use
      • Pending Plug/Pull Services
      • SetConfiguration service bigger than internal buffer
      • Other packet fragmentation errors.

      Its is expected, that the Channel Init does not activate the configuration sent by SetConfiguration service.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  AMesser Andreas Messer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: