Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-127

Out of Memory when Loading Databases with more that 5 submodules

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: V3.6.6.0
    • Fix Version/s: V3.6.7.0
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The netRAPID52 Firmware is not able to load a database with more than 5 Submodules because of no memory available. The Problem is even more evident for builds from latest source code. The netRAPID is not able to load databases at all.

      Issue was created from Testreport TRS1408011

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: