Details
Description
The firmware no longer supports these parametertypes:
- PNS_IF_SET_OEM_PARAMETERS_TYPE_1
- because it contains SerialNumber which shall be exclusivly be set via DDP
- for applications implementing a Profile, handling of I&M in application is required
- PNS_IF_SET_OEM_PARAMETERS_TYPE_2
- because it contains SerialNumber which shall be exclusivly be set via DDP
- PNS_IF_SET_OEM_PARAMETERS_TYPE_4
- service was marked as deprecated and is now removed
- SNMP sysName is writeable via network and shall no longer be configured by application
- PNS_IF_SET_OEM_PARAMETERS_TYPE_14
- because it contains HardwareRevision which shall be exclusivly be set via DDP
- use PNS_IF_SET_OEM_PARAMETERS_TYPE_18 instead
- PNS_IF_SET_OEM_PARAMETERS_TYPE_15
- because it contains OrderID which shall be exclusivly be set via DDP
- use PNS_IF_SET_OEM_PARAMETERS_TYPE_18 instead
- PNS_IF_SET_OEM_PARAMETERS_TYPE_17
- firmware behavios was changed so that by default the IP is kept when BusOff is set. This is a general definition for all new Hilscher firmware (independend from the protocol)
Attachments
Issue Links
- relates to
-
PSPNSV4-1252 Add support for PNS_IF_SET_OEM_PARAMETER_REQ parametertype 18
- Closed
-
PSPNDIF-146 remove unsupported SetOem ParameterTypes from public API Header
- Closed